Skip to content
  • Medical
    • P-DERM® Silicone Gel Adhesives
    • P-DERM® Hydrogel Adhesives
    • P-DERM® Non-Adhesive Films
    • P-DERM® Tapes & Medical Grade Adhesives
  • Thermal Interface Materials
    • P-THERM® Gap Fillers
    • P-THERM® Phase Change Materials
    • P-THERM® Heat Spreaders
    • P-THERM® Adhesives
  • Shielding & Grounding Materials
    • P-SHIELD® Fabric Tapes
    • P-SHIELD® Film Tapes
    • P-SHIELD® Foil Tapes
    • P-SHIELD® Foam Tapes
    • P-SHIELD® Conductive Adhesives
    • P-SHIELD® Conductive Fabrics without Adhesive
    • P-SHIELD® Conductive Foam without Adhesive
  • General Industrial
    • General Industrial Adhesives
    • Single Coated Film Tapes
    • Double Coated Film Tapes
    • General Industrial Films
    • Non-Conductive Silicone Foam
  • Resources
    • News and Events
    • Technical Data Sheets
      • P-DERM® Skin Contact
      • P-THERM® Thermal Management
      • P-SHIELD® EMI Shielding & Grounding
      • General Industrial Technical Data Sheets
    • Literature
      • P-DERM® Skin Contact Adhesives Literature
      • P-SHIELD® EMI Shielding and Grounding Materials Literature
      • P-THERM® Thermal Management Materials Literature
  • Careers
Contact Us
Contact Us
Contact Us
  • Medical +
    • P-DERM® Silicone Gel Adhesives
    • P-DERM® Hydrogel Adhesives
    • P-DERM® Non-Adhesive Films
    • P-DERM® Tapes & Medical Grade Adhesives
  • Thermal Interface Materials +
    • P-THERM® Gap Fillers
    • P-THERM® Phase Change Materials
    • P-THERM® Heat Spreaders
    • P-THERM® Adhesives
  • Shielding & Grounding Materials +
    • P-SHIELD® Fabric Tapes
    • P-SHIELD® Film Tapes
    • P-SHIELD® Foil Tapes
    • P-SHIELD® Foam Tapes
    • P-SHIELD® Conductive Adhesives
    • P-SHIELD® Conductive Fabrics without Adhesive
    • P-SHIELD® Conductive Foam without Adhesive
  • General Industrial +
    • General Industrial Adhesives
    • Single Coated Film Tapes
    • Double Coated Film Tapes
    • General Industrial Films
    • Non-Conductive Silicone Foam
  • Resources +
    • News and Events
    • Technical Data Sheets +
      • P-DERM® Skin Contact
      • P-THERM® Thermal Management
      • P-SHIELD® EMI Shielding & Grounding
      • General Industrial Technical Data Sheets
    • Literature +
      • P-DERM® Skin Contact Adhesives Literature
      • P-SHIELD® EMI Shielding and Grounding Materials Literature
      • P-THERM® Thermal Management Materials Literature
  • Careers
    • Medical
    • Thermal Interface Materials
    • Shielding and Grounding Materials
    • General Industrial
    • Industries
    • News and Events
    • Technical Data Sheets
    • Literature
  • Contact Us →
P-DERM® PS-1857 is a trilaminate consisting of high adhesion silicone gel adhesive, polyurethane film and medical pressure sensitive adhesive. PS-1857 is supplied with a 100 micron LDPE liner on the silicone gel adhesive side and an 55# bleached kraft siliconized release liner on the acrylic side of the construction.
5369
P-DERM®

PS-1857

• Excellent Instantaneous Tack
• Atraumatic Removal from Skin
• Hypoallergenic
• Ability to be Removed and Repositioned
• Excellent Converting Properties
PropertyValueTest Method
Thickness (excluding liner)0.32mmQSP-726
Silicone Gel Coat Weight 250 gsmQSP-724
Carrier TypePolyurethane Film--
Carrier Thickness25 micronQSP-726
Medical Adhesive Coat Weight38 gsmQSP-724
Silicone Adhesion1.8 N/25mmQSP-723
Acrylic Adhesion5 N/25mmQSP-722
Continuous Use Conditions10 - 70 CQSP-754
BiocompatibilityCytotoxicity: Pass
Primary Dermal: Pass
Buehler Sensitization: Pass
ISO 10993
Recommended Sterilization MethodEthylene Oxide--
Specific tests should be performed by the end user to determine the product suitability for the particular application.
DOWNLOAD PDF
Innovations in adhesives, tapes and coatings
Contact
+1.888.533.7004 sales@polymerscience.com
Certifications
ISO 9001:2015 ISO 13485:2016
Technical Data Sheets
  • P-DERM® Medical Materials
  • P-THERM® Thermal Interface Materials
  • P-SHIELD® Shielding & Grounding Materials
  • General Industrial Materials
  • Cookie Policy
Copyright © 2026 Polymer Science, Inc. All Rights Reserved.
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
View preferences
  • {title}
  • {title}
  • {title}